Adinizer

Adinizer

Adinizer: Cutting-Edge Regenerative Technology

Adinizer transforms adipose tissue processing with its patented ultra-sharp blade system, enabling precise isolation of stromal vascular fraction (SVF) for advanced medical applications.

 

Adinizer

Safe and Certified for Medical Excellence

Adinizer, certified by CE, FDA, KFDA and TGA, offers reliable solutions for regenerative treatments in orthopedics, aesthetics, and gynecology.

Regenerative application in 4 steps

Autologous Adipose Tissue Harvesting

Adipose tissue is safely harvesting under appropriate sterile conditions by creating negative pressure with the specially designed fat harvesting cannula in the Adinizer Smart Kit.

1
Autologous Adipose Tissue Harvesting

Mechanical Separation in a Closed Sterile System

Following the initial centrifugation, the adipose tissue harvested from the patient is subjected to a cutting process through the 2,400μ, 1,200μ, 600μ and 400μ Adinizer blades situated between the two injectors. This results in the separation of the parenchymal cells and stromal cells present within the adipose tissue.

2
Mechanical Separation in a Closed Sterile System

Mechanical SVF Isolation with Smartfuge

The mechanical SVF, comprising up to 99% live cells, is obtained from adipose tissue by centrifugation at 1200 G for 5 minutes in a Smartfuge centrifuge. This device is designed with an optimal weight to prevent vibration, reaches the desired rotation speed rapidly, and rotates with a radius angle of 90° to ensure equal distribution of internal pressure.

3
Mechanical SVF Isolation with Smartfuge

Regenerative Cell Cocktail Application

The mechanical SVF treatment has been demonstrated to result in a reduction in wrinkles and a younger appearance, mechanical SVF-enriched adipose tissue transfer has been shown to be a viable option for a number of areas, including the face, hands, legs, buttocks, breasts, and body fullness.

4
Regenerative Cell Cocktail Application

Areas of Use

Cell Count Results

  • Total Cells: 1.87 × 10⁸ cells/mL
  • Nucleated Cells: 7.63 × 10⁶ cells/mL
  • Non-Nucleated Cells: 1.79 × 10⁸ cells/mL
  • Nucleated Cell Viability Rate: 95.8%
  • Average Nucleated Cell Size: 13.2 µm
  • Total Number of Cells: 83776
  • Number of Nucleated Cells: 3424
  • Number of Viable Nucleated Cells: 3280
  • Number of Non-Viable Nucleated Cells: 144
  • Number of Non-Nucleated Cells: 80352

Protocol

  • Protocol Name: ASSUMED
  • Reconstitution Factor: 1.11
  • Min. Cell Size: 3 µm
  • Max. Cell Size: 60 µm
  • Cell Size Range: 3~60 µm
  • Noise Reduction: 5
  • Roundness: 60%
  • Fluorescence Threshold: 5
  • Green Exposure: 15
  • Red Exposure: 5
  • Green Calibrated Value: 0x7AE0
  • Red Calibrated Value: 0x55D

Easy to Use

  • Easily on-site use in the operating rooms and clinics.
  • Ready to use process set
  • Short processing time

Safe Applications

  • Closed system processing kit
  • Certified product
  • Enzyme-free mechanical SVF
  • Does not cause allergic reactions
  • Non-toxic
  • Contains no synthetic components

Adinizer Gallery